Start with three questions: how many doors your floor and your inventory can support, where the compressor should sit for the room it will live in, and whether staff (or guests) need to see the product without opening the door. Answer those, then confirm the cabinet carries the right sanitation and electrical listings for your side of the border. This reach-in refrigerator buying guide walks through each decision in that order, with sizing numbers taken from the cabinets we actually carry.
Reach-In Refrigerator Buying Guide: The Short Version
- Doors / sections: one section suits a small kitchen or a dedicated station; two sections is the default for a full-service restaurant; three sections is for commissaries, banquet kitchens and high-volume prep.
- Top mount or bottom mount: pick top mount where flour, grease or mop water sits at floor level; pick bottom mount where the ceiling zone is hot or tight and you want the condenser easy to reach.
- Solid or glass door: solid for back-of-house storage; glass when people need to read the shelves at a glance.
- Certification: look for NSF/ANSI 7 (or ETL Sanitation) for the food zone, plus a UL or ETL electrical listing in the US and a Canadian mark (cUL, cULus, cETLus or CSA) in Canada.
How to Size a Commercial Refrigerator: 1, 2 or 3 Doors
A commercial reach-in refrigerator is sold by section, each with its own door or pair of half doors. The ranges below come from the reach-in refrigerators in the DFE catalog.
| Sections | Typical width | Typical capacity | Best fit |
|---|---|---|---|
| 1 section | About 24" to 30" | About 18 to 25 cu ft | Cafes, food trucks with a commissary, bars, a dedicated pastry or garde manger station |
| 2 sections | About 47" to 58" | About 39 to 55 cu ft | Most full-service restaurants, pizza shops, school and hospital kitchens |
| 3 sections | About 76" to 86" | About 64 to 84 cu ft | Commissaries, banquet and catering kitchens, kitchens supporting several service periods |
Depth matters as much as width. Most cabinets in this class run about 26" to 33" deep before the door opens, and the door swing is what usually catches buyers out. The Arctic Air AR72, for example, is 32" deep but needs about 59.5" of depth with a door open at 90 degrees. Measure your aisle with the door open, not closed.
A practical sizing method
- Count your peak load between deliveries. Walk the current cooler (or your planned menu) on the day before your biggest delivery, and list what has to be cold: cases of produce, dairy, proteins, prepped product in pans and Cambros.
- Convert it to shelves, not cubic feet. Cubic feet ratings include space you can't load. Count how many shelf levels of product you hold, and check how many shelves each section ships with (three per section is common) and how far they adjust.
- Check pan compatibility. If you stage on full 18" x 26" sheet pans, confirm the cabinet takes them or accepts tray slides. Several two- and three-section models are built for it; the AR72 takes optional full-size sheet pan racks behind each door.
- Leave room for air. Manufacturers tell you to keep product off the back wall and out of the airflow, so size for gaps even at peak load.
- Round up a section if you're between sizes. Adding a second unit later costs another compressor, circuit and stretch of wall.
If the space you have can't take a full-height cabinet, look at undercounter refrigeration for the line and keep the reach-in for bulk storage.
Top Mount vs Bottom Mount Compressor
Every self-contained reach-in has its condensing unit either above the cabinet or below it. Neither is better in general; each is better in a particular room.
| Factor | Top mount | Bottom mount |
|---|---|---|
| Floor debris | Condenser breathes air away from flour, grease and mop water at floor level | Condenser sits near the floor and pulls in what gets swept past it, so it needs more frequent cleaning |
| Ambient heat | Sits in the hottest air in the room, near the ceiling or a hood | Sits in the coolest air in the room |
| Interior layout | Often more usable interior height | The bottom shelf is raised, so less bending to reach low product |
| Service access | Needs a ladder; needs clearance above the cabinet | Service and condenser cleaning at floor level, often on a slide-out rail |
| Ceiling height | Taller overall and needs clearance above for airflow | Works under low soffits and shelving |
The interior-height difference is real. Omcan's top mount single-door cabinet lists 56.8" of usable interior height against 51.5" in its bottom-mount equivalent. On the clearance side, Traulsen asks for 12" of open space above its G-Series cabinets so the condensing unit can breathe. If your kitchen has a low ceiling, heavy shelving above the cabinet or a hood line, that requirement can decide the question for you.
Rule of thumb: bakeries, pizza shops and fry-heavy kitchens lean top mount; hot, cramped kitchens and spaces where staff will clean the condenser themselves lean bottom mount. Either way, a condenser that gets cleaned on a schedule outlasts one that doesn't. If an existing unit is already struggling, our guide to a commercial refrigerator not cooling covers the common causes, starting with dirty condenser coils.
Solid Door vs Glass Door Refrigerator
Solid doors are the default for back-of-house storage: they insulate better than glass and stand up to carts and elbows. If guests never see the product, buy solid.
Glass doors earn their place when seeing the product changes behavior: a deli or cafe where guests choose, a banquet staging area where servers need to find a tray fast, or a line where cooks waste door openings hunting for one container. Glass doors can also add depth: the Fagor QVR-2G-N is 33" deep against 31-1/8" for its solid-door twin. Plan to wipe the glass daily.
Two other door choices to settle at the same time:
- Full-height vs half-height doors. Half doors let out less cold air per opening and suit a busy line; full doors are simpler to load with large items. Some models, such as the Traulsen G-Series, are offered either way.
- Hinging and pass-thru. Confirm which side the door hinges on before you order, so it opens away from your workflow. If the cabinet sits between kitchen and service, a pass-thru model with doors on both sides can replace two cabinets.
Certifications: NSF/UL in the US, CSA/ULC Marks in Canada
A reach-in needs two different kinds of listing, and inspectors on both sides of the border will look for them.
Sanitation (food zone)
NSF/ANSI 7 is the standard for commercial refrigerators and freezers that store or display food. It covers materials, cleanability and construction of the food zone, plus a performance requirement for storage refrigerators. ETL Sanitation is Intertek's certification to the same NSF/ANSI standards and is widely accepted by health departments. Either should appear on the data plate or spec sheet.
Electrical safety
- United States: look for a UL or ETL listing. Both are nationally recognized testing laboratories.
- Canada: electrical equipment sold or installed in Canada generally has to be certified by a body accredited by the Standards Council of Canada. Look for a Canadian mark: cUL, cULus, ULC, cETLus or CSA. A US-only UL mark is not enough on its own; UL itself flags that as a common compliance mistake.
The underlying safety standards have changed recently. UL 471 and CSA C22.2 No. 120, the long-standing commercial refrigerator standards, were superseded by the harmonized UL/CSA 60335-2-89 standard, effective September 29, 2024. Existing certifications stay valid as long as the product isn't modified, so you will see both on spec sheets for a while.
Check the listings on the specific model, not the brand; marks can differ within one product family.
Temperature, Energy and Code Requirements
- US holding temperature: the FDA Food Code requires cold time/temperature control for safety (TCS) food to be held at 41°F (5°C) or below. Your state or local health department adopts and enforces its own version, so confirm locally.
- Canada holding temperature: provincial food premises rules generally require potentially hazardous food to be kept at 4°C (about 39°F) or colder. British Columbia's Food Premises Regulation, for example, sets that limit and also requires refrigeration equipment to have a thermometer accurate to within 1°C. Check your province's regulation and your local public health unit.
- Holding range: because Canadian limits are tighter, look at the cabinet's rated range. Cabinets that hold 33°F to 38°F or 34°F to 39°F give you headroom under 4°C; a cabinet whose range tops out at 41°F should be set toward the low end.
- Energy: ENERGY STAR certified commercial refrigerators average about 20% more efficient than standard models, using components such as ECM fan motors and high-efficiency compressors. In Canada the program is administered by Natural Resources Canada (NRCan), and commercial refrigerators are also covered by federal minimum efficiency regulations. Utilities in both countries often offer rebates on certified models; check the ENERGY STAR rebate finder in the US and your provincial or local utility in Canada before you buy.
- Electrical: most single-, two- and three-section reach-ins plug into a standard 115V/120V NEMA 5-15P outlet. Manufacturers typically call for a dedicated circuit and no extension cord.
Reach-In Buying Checklist
- Measure the space, the door swing, the path in through your doors and hallways, and the clearance above the cabinet.
- Choose section count from your peak load between deliveries, not your average day.
- Choose top or bottom mount based on floor debris, room heat and ceiling clearance.
- Choose solid or glass, full or half doors, hinging side and whether you need a pass-thru.
- Confirm NSF/ANSI 7 or ETL Sanitation, plus the electrical mark for your country.
- Check the rated temperature range against your local code.
- Confirm the plug type and that you have a dedicated circuit for it.
- Look for ENERGY STAR and check local utility rebates.
- Compare warranty terms, especially compressor coverage, and who services the brand in your area.
- Read the manufacturer's installation manual before delivery; the warranty depends on its clearances and setup steps.
Reach-In Refrigerators Worth a Look
These cover the main decisions above across five brands. Browse the full reach-in refrigerators collection to compare every size.
- One section, top mount: the Omcan RE-CN-0029-TM 29" top mount reach-in refrigerator holds 21.5 cu ft at 33°F to 40°F, plugs into a 120V NEMA 5-15P outlet, and has the extra interior height that comes with moving the compressor overhead. A good fit for a bakery or pizza shop with limited wall.
- Two sections, top mount: the Traulsen G-Series G20010 two-section solid door reach-in holds 46.02 cu ft at 34°F to 38°F in a stainless interior and exterior, is ENERGY STAR listed, and comes with full- or half-height doors. Traulsen lists UL, CSA and NSF, and backs it with six years parts and labor.
- Two sections, bottom mount, Canadian-built: the Habco SE46HCSA two solid door stainless reach-in holds 34°F to 39°F, breathes entirely from the front so it can be built in tight, and uses a slide-out Cassette refrigeration system that can be swapped without giving up the cabinet. It is cULus listed and NSF certified.
- Two sections, glass door: the Fagor QVR-2G-N two glass door reach-in gives 52 cu ft behind dual-pane glass with LED lighting in each section, holds 33°F to 38°F, and still takes full 18" x 26" sheet pans, so it can move between display and production.
- Three sections, bottom mount: the Arctic Air AR72 three door reach-in refrigerator holds 72 cu ft at 33°F to 41°F on a standard 115V circuit, is ENERGY STAR approved, and has a front-accessible bottom-mount condensing unit on a slide-out rack for easy cleaning.
Need frozen storage as well? The same sizing and mounting logic applies to reach-in freezers, and the full reach-in refrigeration category puts refrigerators, freezers and dual-temperature cabinets side by side.
Comparing two cabinets and can't decide? Send us your space measurements and menu volume and our team will help you narrow it down.
Frequently Asked Questions
What size reach-in refrigerator does a small restaurant need?
Most small full-service restaurants land on a two-section reach-in of roughly 40 to 50 cu ft, often paired with undercounter units on the line. A cafe or bar with limited prep can usually run on a single section. Size from your heaviest stretch between deliveries, not your average day.
Is a top mount or bottom mount reach-in better?
Top mount is better where the floor is dirty, dusty or wet, such as a bakery, pizza shop or fry-heavy kitchen. Bottom mount is better in hot or low-ceilinged kitchens and where staff will clean the condenser themselves, because it sits in cooler air and is reachable at floor level.
Can I use a US-listed refrigerator in Canada?
Only if it carries a Canadian certification mark, such as cUL, cULus, cETLus or CSA. A US-only UL or ETL listing isn't accepted on its own. Check the data plate or spec sheet of the exact model before ordering.
What temperature should a reach-in refrigerator be set to?
Product must stay at 41°F (5°C) or below under the FDA Food Code in the US, and generally at 4°C (about 39°F) or below under provincial rules in Canada. Many operators set the cabinet a few degrees colder than the limit to cover door openings, and verify with a thermometer inside the cabinet.